Rectifying faults / maintenance and cleaning – Dexaplan BA 611 User Manual
Page 13
12
GB/IE
Rectifying faults
Fault
Cause
Remedy
Motion detector
detects motion
without apparent
reason.
Pets, air move-
ments, direct
light, etc.
Change the
position of the
motion detector.
Use a masking
sticker to
restrict a par-
ticular part of
the detection
angle / range.
The range of the
motion detector
is not adequate.
Ambient temper-
ature is too high
(20°C is optimal).
Change the
position of the
motion detector.
Device is mounted
too low or too
high.
Change the
mounting
height or the
inclination of
the motion
detector.
The
LED
flashes regularly.
There is no
backup battery
connected or the
connected back-
up battery is too
weak.
Connect a new
backup battery.
The called
number does
not receive a
call on alarm.
The telephone
number was in-
correctly or not
entered.
Enter the tele-
phone number
again.
Fault
Cause
Remedy
Dialling function
is switched off
(
appears on
the LC display.
Set the dialling
function on.
(
does not
appear on the
LC display.
The telephone
line is faulty.
Check the
telephone line
with an
analogue tele-
phone.
The device
does not react
to the pass-
word.
You have not
yet given a
command after
password entry.
Press the OK
key
y
to arm/
disarm the
device.
Press the PROG
key
r
to enter
settings mode.
The password
entered is
wrong.
Enter the cor-
rect password.
If you have
forgotten the
password, set
the device back
to the factory
settings as de-
scribed in the
section “Chang-
ing the pass-
word”.
Fault
Cause
Remedy
Your settings
were not
stored.
The settings
were not con-
Press the OK
key
y
to
settings.
There are other
faults
Carry out a re-
set (see section
“Making the
settings” item
“Reset”).
Should you have further questions or problems please
-
tion on problem handling.
Maintenance and cleaning
Maintenance of the alarm system
You should regularly check the device to see that it is
safe and working properly.
Cleaning
Before you clean the device, pull the mains adapter out
of the mains socket. Use a dry or slightly moist cloth for
cleaning the device. Never immerse the device in water.
Do not use solvents to clean the device.
Rectifying faults / Maintenance and cleaning