Select the type of consumption you wish to consult by pressing
button C1/C2:
C1:
Cumulated total since first startup (non erasable)
C2: Total since last reset

View the consumption of all subscribed price option periods by
pressing SELEC.

Displays the maximum mean power reached, at end of reading
(before returning to the current display).

3

2

1

PRINCIPLE

On

Flashing

Off

No power supply

Normal

operation

LED

status

with

electromechanical

meter

DELTA DORE

Bonnemain - 35270 COMBOURG - France

E-mail : [email protected]

Device compliant with the requirements of directives 2004/108/CE (Electromagnetic Compatibility)

and 2006/95/CE (Low-Voltage Safety).

Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore.

4. How to read your consumption indicators ?

5. Meter indicator light

If you have contracted the Off-Peak option.

E.g. Consultation of C2 total.
Current price period:
Peak Hours

Resetting the Total Consumption Indicators to Zero (C2 only)

Press button RESET C2 for approximately 10 seconds to reset all total consumption indicators to zero, as well as maximum
mean power.
Press SELEC. to check.

Maximum Mean Power Reached

Every 6 minutes, the

TYWATT 30 measures the maximum mean power reached. If the measured value does not exceed the

maximum value displayed during a 6-minute acquisition period, the

TYWATT 30 will continue to display the previous value.

HP = Peak hour
HC = Off peak hour

6. Technical characteristics

• 230 V, 50 Hz power supply, ±10%
• Insulation class II, with functional earth
• Power consumption: 0.5 VA
• 1 off-peak hours contact input, 230 V
• 1 single-phase remote information bus input for electronic

meter

• 1 CT input, current measurement by external current

transformer (internal Ø: 10 mm max.)

• Rated operating current: 2 to 90 A , Cos

ϕ

= from 0.8 to 1

• Storage temperature: -10°C to +70°C
• Operating temperature: 0 to +40°C
• Digital display
• Modular unit: 3 modules, h = 53 mm, mounted on DIN rail
• Installation in an environment with normal pollution levels

approximately

6 minutes

approximately

6 minutes

Instantaneous

power (in W)

Instantaneous

power (in W)

C1/C2

C2

C2

C2

C2

RESET C2

C1/C2

C2

C2

C2

C2

5300 Watts

6230 Watts

t

t

Press to display

the C2 total

Press to display

the C2 total

Total Peak

Hour consumption

Total Peak

Hour consumption

Reset total

indicators

to zero

The Off-Peak hour

total is at zero

(As many times

as necessary)

Back to the current

price period display

Total Off-Peak

hour consumption

Maximum mean

power reached

(in Watts)

Back to initial

display

Example :

Mean power

Mean power