Daktronics Scoreboard Dual Hoist User Manual
Page 11

Troubleshooting Guide
7
Section 4: Troubleshooting Guide
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Green Power Light is NOT ON
Main Power Turned Off
Turn on Main Disconnect
E-Stop Button Pressed
Release E-Stop Button
Key Switch Turned Off
Turn on Key Switch
Overtravel Light is ON
Over Travel Limit Reached
Check Over Travel Limits
Overtravel Light is Flashing
Over/Under Capacity (if load
sensing option is included)
Confirm that load is within
the capacity of the hoist
Vortek hoist will not move when
commanded
Main Power Turned Off
Turn on Main Disconnect
E-Stop Button pressed
Check all E-Stop buttons
Motor overloaded
Wait for automatic reset
Hoist has reached limit switch
Move hoist in opposite
direction of travel
Reset Circuit tripped on
wireway
Reset circuit breaker