beautypg.com

3 digit segmentation, 4 schematic, 5 troubleshooting – Daktronics CH-2024V User Manual

Page 20: Digit segmentation -2, Schematic -2, Troubleshooting -2

background image

Maintenance & Troubleshooting

3-2

17 Signal

Input

18

Power input for outputs 1-8 (120V)

19

Power input for driver logic and fan (120V)

20

Power input for outputs 9-16 (120V)

24

Dim option selector

In Drawing A-46539, the numbers on the digits refer to the lamp driver output connector
wired to each digit.



3.3 Digit

Segmentation

Reference Drawing: Segments, 4x7 Lamp Matrix Digit.................. Drawing A-37685

In a digit certain lamp always go on and off together. These groupings of lamps are known as
"segments". Each digit has eight segments, referred by letters A through H. Drawing A-
37685
illustrates these segments and shows which connector pin and wire color is wired to
each segment.



3.4 Schematic

Reference Drawing: Schematic, Pwr&Sig, CH-2024V .................... Drawing A-46437

Pwr&Sig Entrance Components .................... Drawing A-46545


The schematic diagram in Drawing A-46437 shows the power and signal inputs into the
display and to the lamp driver. The component numbers correspond to those shown in
Drawing A-46545.



3.5 Troubleshooting

This is a list of possible problems that may occur and their possible solutions.

Observed Problem

Possible Cause

One lamp won’t light

• Burned-out lamp

• Broken wire behind digit

Digit segment won’t light

• Broken wire

• Poor contact at driver connector

• Internal driver malfunction

Entire digit won’t light

• Broken wire

• Poor contact at connector, pin 7

• Fuse blown in driver

Half the display won’t light

• Service breaker tripped

• Main fuse blown

• Poor contact at main power

connection

• P18 disconnected