beautypg.com

6 ventilation systems, Ventilation systems -8 – Daktronics AF-3300-12-RGB/20-R User Manual

Page 34

background image

Maintenance and Troubleshooting

4-8

DS12

Red

+2.5V

On when +2.5V power supply is functioning.

DS13

Red

+3.3V

On when +3.3V power supply is functioning.

Product Board

LED Color

Function Operation

DS1

Green

+5V

On when +5V power supply is functioning.

DS2

Green

+3.3V

On when +3.3V power supply is functioning.

DS3

Yellow

COM1 TxD

Flashes when transmitting serial information.

DS4

Yellow

COM1 RxD

Flashes when receiving serial information.

DS5

Yellow

Light

Flashes when receiving signal from light sensor

DS6

Yellow

Com 2 RX2

Normal state is ON. When connected to receive RTD input,

the LED will be OFF. The LED flashes when receiving

signal from RTD input device.

Temp Sensor

LED Color

Function Operation

DS1

Green

+5V

On when +5V power supply is functioning.

DS2

Red

Run

A steady flash indicates the controller is running correctly.

Normal flash rate is about once a second. Flashes faster

when the sensor is transmitting temperature or light

information.

4.6 Ventilation Systems

Ventilation fans should be checked after 1,500 hours of operation and every 1,500
hours after that to ensure the display is being cooled properly. Fans should be
checked more often if the display is located in a dusty or harsh weather environment
(i.e. along a gravel road with dust laden air).

1,500 hours is equivalent to 83 days if the display is operated for 18 hours a
day and the power to the display is turned off when not in use

1,500 hours is equivalent to 62 days if the display is running non-stop for 24
hours a day

Each time a module is removed, for whatever reason, take a minute to
inspect the fans

Check the fan blades for dirt and debris; cleaning them and the inside of the
display if necessary – fan blades must be kept clean to maintain fan
efficiency and ensure proper cooling

Spin the fan blades with a pen or pencil to ensure that the bearings are free
and the fan is still in balance


To check the operation of the fans, push the bypass button (momentary contact) on
the thermostat enclosure to temporarily turn the fans on: (The bypass button is
located behind A103, top row, and third module on the left.)

Hold your hand or a piece of light paper in front of the display to detect air
movement

If the fan does not turn or does not operate smoothly, replace it