9


Sig

ter (0A-1127-0255)

The fo


RS-422 Lo


Note: T

a

loop-bac

into th
connections
W-1249

nal Conver

llowing tables list the jack pin-outs for a wire signal converter:










op-Back Test (Outdoor Displays)

his test should be performed with only one jack at a time. Do not connect

k to more than one jack at a time.

Serial Cable (W-1249)
To complete the test, the serial cable must be plugged

e signal converter. This table lists the pin

when using a serial cable (Daktronics part#

) below.

DB9-F

DB25-F

Pin 3 – TX

Pin 2 – TX

Pin 2 – RX

Pin 3 – RX

Pin 5 – GND

Pin 7 - GND

Loop-Back Test: To perform a loop-back, for testing
purposes only, use the spare plug in the signal converter
and connect the following using copper conductor
jumpers. Refer to Figure 10 on the right. (To eliminate
the display, pull out the phoenix plug with the signal
wires connected into it.)






gnal Converter


Figure 9:
RS-232/RS-422 Si

J1 – 25 Pin DB-F

PIN

OPERATION

2 TX-P

(out)

3 RX-P

(in)

7 GND

J2 and J3 –

RJ/45

PIN

OPERATION

1 GND
2 TX-N

(out)

3 TX-P

(out)

4 RX-N

(in)

5 RX-P

(in)

6 GND

J4 and J5 –

Phoenix

PIN

OPERATION

1 GND
2 RX-P

(in)

3 RX-N

(in)

4 TX-P

(out)

5 TX-N

(out)

6 GND

Figure 10: Jumpers at RS-232/RS-
422 Signal Converter

J2 and J3

J4 and J5

(Pin 5) TX-N to

(Pin 3) RX-N

OR

(Pin 2) RX-P to

(Pin 4) TX-P

(Pin 4) TX-P to

(Pin 2) RX-P

(Pin 3) RX-N to

(Pin 5) TX-N