beautypg.com

Care and maintenance, Hydrostat drive belt tension adjustment – Dixon 13090-0601 User Manual

Page 32

background image

32

CARE AND MAINTENANCE

HYDROSTAT DRIVE BELT TENSION ADJUSTMENT:

In normal use the hydrostat drive belt tension should be checked after
the first 20 hours of use for normal wear and stretch. It may be
adjusted as follows:

1.

Loosen the idler pulley locking nut until the idler pulley
can be just moved relative to the mounting bracket.

2.

Tighten the tension adjust bolt until the belt is tight
enough to prevent belt slippage. Belt should deflect
approximately 3/8” to 5/8” under moderate
pressure. Do not over tighten.

Note: If belt is over-tightened it will often make a “chattering”

noise.

3.

Retighten the slide locking nut.

4.

Retighten the tension adjust bolt 1/4 turn to set the
lockwasher and prevent loosening of the tension
adjust bolt.

Motor Pulley

Tension Adjust Bolt

Idler Pulley

Cooling Fins

Hydrostatic Drive Belt

Hydrostatic Drive Pulley

This manual is related to the following products: