beautypg.com

Care and maintenance, Hydrostatic pumps, Hydrostat drive belt replacement procedure – Dixon 12828-0603 User Manual

Page 34

background image

34

CARE AND MAINTENANCE

HYDROSTATIC PUMPS:

Before each use, check to be sure that the cooling fins of
the hydrostatic pumps are clean. Excessive accumulation of
oil, dirt, or trash may cause the pumps to overheat.
NEVER WASH ACROSS TOP OF RESERVOIR WITH WATER
OR STEAM. Fill reservoir as required per the maintenance
schedule listed in this book.

HYDROSTAT DRIVE BELT REPLACEMENT

PROCEDURE:

To remove hydrostat pump drive belt:

(The hydrostat pump drive is equipped with a spring loaded
belt take-up).

1. Raise seat. (See instructions on Page 25).

2. Remove hold down bolts from belt cover. Remove belt

cover.

3. Rotate the spring loaded take-up idler towards the left

hand hydro pump to provide belt slack for removal.

4. Remove belt.

To install hydrostat pump drive belt:

1. Rotate the spring loaded take-up idler towards the left

hand hydro pump.

2. Install belt per diagram.

3. Re-attach belt cover.

4. Return the seat to the operating

position.