Tools required, Assembly procedure, Move to desired location – Cybex 16085 Plate Loaded Chest Press User Manual
Page 8: Remove foot glides, Securely anchor machine to floor

• Area is not in the vicinity of high humidity, such as in the vicinity of a steam room, sauna, indoor pool
or outdoors. This unit is designed to function normally in an environment with a relative humidity
range of 30% to 75%.
Exposure to extensive water vapor, chlorine and/or bromine could adversely affect parts of the unit.
• Area maintains an ambient temperature range of 50° F (10° C) to 104° F (40° C) degrees.
Tools Required
• Flat head screwdriver
• Rubber mallet
Assembly Procedure
Two people will be required for this procedure.
Read and understand all instructions thoroughly before assembling this unit. Check all items
carefully. If there is damage, see the Customer Service section of this manual for proper procedure
to return, replace, or reorder parts.
Move to desired location
Remove foot glides
Plastic shipping foot glides are used on Cybex Strength Systems machines to protect the bottom of
machines during transportation. These foot glides must be removed before a machine is placed in
service, the shipping foot glides will cause the machine to be unstable.
Remove glides:
To avoid serious injury or property damage, remove foot glides before placing unit in service. If guides
are not removed unit will not be stable
1. Raise the foot of the machine slightly off the floor remove foot glides. Do not install weight plates (if
applicable) until all foot glides have been removed.
2. Loosen each foot glide by striking foot glide with rubber mallet.
3. Pry off foot guide using a flat head screwdriver.
4. Place rubber feet (supplied with machine) on each foot of the frame.
Securely anchor machine to floor
Owner should not allow equipment to be used until it is properly anchored as described below.