beautypg.com

Service procedures, Continued – Desa BY35CEH User Manual

Page 10

background image

105522

10

AIR OUTPUT, AIR INTAKE, AND LINT
FILTERS

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using 5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see Preventative Maintenance
Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters

PUMP PRESSURE ADJUSTMENT

1.

Remove pressure gauge plug and plastic cap (BY35CEH and
BY70CEH only) from filter end cover.

2.

Install accessory pressure gauge (part number HA1180).

3.

Start heater (see Operation, page 5). Allow motor to reach full
speed.

4.

Adjust pressure. Turn relief valve to right to increase pressure.
Turn relief valve to left to decrease pressure. See specifica-
tions below for correct pressure for each model.

5,

Remove pressure gauge. Replace pressure gauge plug and plas-
tic cap (BY35CEH and BY70CEH only) in filter end cover.

Figure 13 - Air Output, Air Intake, and Lint Filters, BY35CEH and
BY70CEH Models

SERVICE PROCEDURES

Continued

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Air Intake
Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, BY100CEH
and BY150CEH Models

Fan
Guard

Figure 15 - Pressure Gauge Plug and Plastic Cap Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 16 - Adjusting Pump Pressure

Pump
Pressure

Model

(PSI/Bar)

BY35CEH

2.9/0.200

BY70CEH

4.9/0.338

BY100CEH

4.9/0.338

BY150CEH

5.5/0.380

Relief
Valve

Plastic Cap

SERVICE PROCEDURES