5. Test GFCI switch before each use, to test:

a. Press test button (b), indicator light will disappear.

c. Press reset button (c) to use unit. If indicator light does not reappear

DO NOT use unit, see troubleshooting guide.

6. Con

nect the high pressure hose (i) to the water outlet on the unit. The

water outlet is marked OUT.

7. Assemble quick-connect adapter (k) to water inlet.

8. Connect the quick-connect (j) to the water supply hose.

Risk of property damage. To reduce the possibility of
contamination always protect against backflow when

connected to a potable water system.

9. Connect quick-connect (j) to quick connect adapter (k) at the water inlet.

NOTE: The water supply must provide a minimum of 5 gallons per minute.
10.
Make sure high pressure hose and water supply hose are securely

connected.

Risk of fluid injection and laceration. Always relieve sys tem
pres sure before changing

accessories. Place on/off switch in off
position, turn off water sup ply, and pull gun
trigger until water stops fl owing.

11. Connect the desired nozzle to spray

wand. To connect rotary (a) and variable
spray nozzle (b), turn clockwise until it
snaps into place. To remove nozzle, turn
nozzle counter clockwise to remove. To
connect chemical application unit (c)
see How To Use Cleaning Solution
Application Unit
in this section.

12. Turn water supply on.

j

k

j

a

b

c

i

k

This manual is related to the following products: