If using the IDC:
Carefully observe the proper orientation of the Tip-
Ring leads. Do not remove the insulation from the
wire and maintain the wire twist.
Insert each pair
of wires into the appropriate IDC connector about ½”.

Press the IDC closed, until the IDC latches lock into
place. It will take some force to close the IDC, with
the thicker wire gauges taking more effort.

If using the RJ11:
With the RJ11 latching tab facing the installer, press it
into the appropriate opening, until it locks into place.
See table below for pin assignment.

RJ11 Wiring

Modem Line Phone

Pin Connection Pin

Connection

Pin

Connection

1

1

Line 2 Tip

1

Phone 2 Tip

2 DSL Ring

2

Line Ring

2

Phone Ring

3 DSL Tip

3

Line Tip

3

Phone Tip

4

4

Line 2 Ring

4

Phone 2 Ring

Testing

To test the CPE-01V for correct operation, simply lift the phone handset - you should hear dial tone.

The modem status light should be illuminated indicating xDSL service. You may have to refer to the xDSL modem
users guide to correctly interpret the meaning of its status indicators.

Once tested, secure the wires.


Warranty

The CPE-01V is covered by a 3-year warranty under normal operating conditions. Defective units should be returned to
Comtest Networks where they will be replaced or repaired and returned to the user. The CPE-01V contains no user
serviceable parts. Opening the plastic housing voids the warranty and may expose the user to hazardous voltages.

For Assistance
[email protected]
1- 877-369-5499
www.comtestnetworks.com

½”