beautypg.com

Direct connection, Ireplace, Nsert – Dansons Group IPP User Manual

Page 19: Nstallation, Full chimney reline

background image

Can

adian Comfort Industries V04

19

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

F

IREPLACE

I

NSERT

I

NSTALLATION

CONTINUED

When installing into a masonry chimney, it is recommended that the exhaust vent be extended to the top of
the chimney as shown to the lower right. However, if the vent pipe does not extend to the top of the
chimney, the pipe must extend a minimum of 18” above the damper.

You must seal the damper area with a steel plate when using the direct connection method.

The Vent Pipe Must Extend Above The Damper into the first tile of the flue liner (Figure 25) in the USA and
to the top of the chimney CANADA (Figure 26). The chimney must not be corroded or damaged in any way
for this type of installation to be permitted. A direct vent may be made through the chimney structure if local
codes permit.










































Figure 25

Figure 26

Metal
Sealing Plate

18” min.
length

18”

18”

18”

8”

Note: This installation

allowed in Canada

not

DIRECT CONNECTION

6”

Liner Support

Deluxe Cap

Optional

Metal Plate

6”

18”

8”

FULL CHIMNEY RELINE

Note: This installation recommended

for all chimney installations!

is

This manual is related to the following products: