Ami or hdb3/b8zs, E1 bal or unbal, T1/e1 balanced 15 pin d-sub pinout – Comtech EF Data CIC-50 User Manual
Page 16: 2 ami or hdb3/b8zs, 3 e1 bal or unbal

.
CIC-50 T1/E1 G.703 Interface Converter
4
Rev. 1
3.1.2
AMI or HDB3/B8ZS
For both T1 and E1 formats, this sets the G.703 output to either the uncoded Alternate
Mark Invert (AMI) format, or to the appropriate zero substitution line code used for T1
(B8ZS) or E1 (HDB3).
3.1.3
E1 BAL or UNBAL
For E1 only, this adjusts the impedance on the G.703 input between 120 ohms for
balanced and 75 ohms for unbalanced. The 15-pin D-sub connector should be used for
balanced and the two BNC connectors for unbalanced. For T1 this selection is a ‘don’t
care’ since unbalanced is not an option, and the D-sub connector must always be used.
3.1.4
T1/E1 BALANCED 15 PIN D-SUB PINOUT
Pin
Balanced G.703 Tx (Inputs)
3, 11
Balanced G.703 Rx (Outputs)
2, 4
Ground
6, 7, 8, 14, 15
Don’t Connect (reserved for redundancy system)
- CDD-880 (124 pages)
- CDM-800 (130 pages)
- ODMR-840 (184 pages)
- CDM-750 (302 pages)
- CDM-840 (244 pages)
- SLM-5650A (420 pages)
- CTOG-250 (236 pages)
- CDM-700 (256 pages)
- CDM-760 (416 pages)
- CDM-710G (246 pages)
- CDM-600/600L (278 pages)
- CDMR-570L (512 pages)
- CDM-625 (684 pages)
- CDM-625A (756 pages)
- CDD-564A (240 pages)
- CDD-564L (254 pages)
- CLO-10 (134 pages)
- MCED-100 (96 pages)
- CDMR-570AL (618 pages)
- CDM-600 LDPC (2 pages)
- BUC Power Supply Ground Cable (2 pages)
- MPP70 Hardware Kit for CDM-570L (4 pages)
- MPP50 Hardware Kit for CDM-570L (4 pages)
- CDM-625 DC-AC Conversion (4 pages)
- CDM-625 DC-AC Conversion with IP Packet Processor (4 pages)
- DMDVR20 LBST Rev 1.1 (117 pages)
- DMD-2050 (342 pages)
- DMD2050E (212 pages)
- DMD1050 (188 pages)
- OM20 (220 pages)
- QAM256 (87 pages)
- DD240XR Rev Е (121 pages)
- MM200 ASI Field (5 pages)
- DM240-DVB (196 pages)
- MM200 (192 pages)
- CRS-150 (78 pages)
- CRS-280L (64 pages)
- CRS-170A (172 pages)
- CRS-180 (136 pages)
- SMS-301 (124 pages)
- CiM-25/8000 (186 pages)
- CiM-25 (26 pages)
- CRS-500 (218 pages)
- CRS-311 (196 pages)
- CIC-20 LVDS to HSSI (26 pages)