CiM-25 Quick Start Guide
Rev. 0
Quick Start Procedure
CD/CIM25QSG.IOM
5
1.3 N
ETWORK
C
ONFIGURATION
The default network configuration settings are:
IP:
10.6.30.1
Admin Name:
admin
Admin Password:
1234
The CiM-25 has been designed to support a means of allowing a customer to change the
IP Address or reset the unit back to the factory default settings. Use the procedure in
section 1.3.1 to reset the CiM-25 to factory network defaults. Use the procedure in 1.3.2
to change the CiM-25 network IP Address.
1.3.1 R
ESETTING TO
F
ACTORY
D
EFAULTS
Perform the following steps:
1
Disconnect the CiM-25 from both the interfacing equipment and the Ethernet Network.
2
Connect the CiM-25 to the serial port of a PC using a cable defined below (null cable):
CiM-25 pin 2 to PC pin 3
CiM-25 pin 3 to PC pin 2
CiM-25 pin 5 to PC pin 5
2
3
5
DB
-9
2
3
5
DB
-9
To CiM-25 Device
(M/F Depending
on Unit)
To Computer
(Ususally Female)
Figure 1. Null Cable Diagram
3
Power the CiM-25/300A using the Power Jack connector and a external 5 Vdc power supply.
4
Using a Serial Communication application such as Terminal, ProComm, etc., configure the
PC’s serial port to:
Baud: 19200
Data rate: 8-N-1
5.
To reset the CiM-25, enter the following command:
Command:
<0/RST=’cr’
Response:
>0/RST=