Installing trim, Option of wall wash, Electrical connection – Coloronix 6″ Recessed RGBW Downlight User Manual
Page 11

Installing Trim
Installing assembly: insert torsion springs into spring receivers (found in housing). For
3” round, insert trim held in place by spring blades.
WARNING: Power must be off before connecting LED trim.
Option of Wall Wash
For 4”x9” wall wash trim, install frame according
to diagram.
Electrical Connection
WARNING: Do not expose bare wires outside wire nut connectors.
1. Per local or “National Electric Code”, provide electrical service to junction
box located on the housing.
a. The insulation of supply wire must be rated for at least 90°C.
b. Junction boxes are rated for:
i. Max. 8 No. 12 AWG Circuit Conductors
ii. Also suitable for at least 90°C
2. Remove cover of junction box.
3. Remove proper round pryout, and then connect junction box with (not
included) proper connector.
4. Using properly sized wire nuts, connect lead wires of junction box (line,
neutral, and ground) to supply lead wires in the fixture.
a. WARNING: Do not leave bare conductors outside wire nut
connectors.
5. Connect green (from electrical service) to the supply side to the green wire
in the junction box. Connect black-to-black, and white-to-white.
a. Any excess wiring and connectors should be put in the junction box.
Then, replace the cover.
NOTE: Supply lead wires should not be connected to a dimmer of any sort.
Page 11 - Coloronix RGBW Recessed Lighting Manual V2.0