3 installation & system setup, Administrator guide – Code Blue 360-DEGREE PEDESTAL MOUNT PUBLIC ADDRESS SPEAKER User Manual
Page 8

Administrator Guide
Code Blue
●
●
●
●
●
This section covers the following units:
CB 1 Series with Public Address, including the 360° PAS Retrofit Kit
CB 5-s with Public Address
CB 2-e with Public Address
WM-180°
The following models are covered in the installation instructions for CB 1 Series with Public
Address or the 360° PAS Retrofit Kit:
CB 1-e
CB 1-s
CB 1-d
Ladder
– to reach the top of the unit.
Security bit
– to secure the PAS top to the adapter ring.
6mm Allen wrench
– to secure the PAS adapter ring to the top of the unit.
3/8
” socket set - to mount the mounting plate containing the new toroid transformer.
Remove 120V AC power from the unit.
3.1.2.1
3.1.3
Remove the existing dome top assembly. Disconnect the red/black and
3.1.3.1
yellow/yellow wiring harnesses connected to the beacon/strobe mounted in the
dome top assembly.
Place the adapter ring on top of the bollard and tighten the three Allen set
3.1.3.2
screws to hold in place (see