beautypg.com

Shut down instructions, To turn the burner off, To turn the pilot off – Drolet SIT 0.820.634 User Manual

Page 20: Optional blower, Optional wall thermostat

background image

ULTRA FLAME DIRECT VENT GAS STOVE

19

Shut down Instructions

To turn the burner OFF

• Push in and rotate the gas control knob clockwise

3

to "PILOT" position. Do not force.

To turn the pilot OFF

• Push in and rotate the gas control knob clockwise

3

to "OFF" position. Do not force.

Optional Blower

The blower control contains a variable speed switch and a thermal switch. When the stove is operating, the
thermal switch will turn on at 120° F, allowing the blower to operate. When the stove cools to 90° F, the
thermal switch turns off the blower in about 40 minutes. This prevents the blower from operating when the
stove is not in use.

The blower not only helps circulate air throughout the room, it also increases the heat transfert efficiency of the
ULTRA FLAME.

NOTE: Wiring, speed control and thermo switch are pre-install at the factory. Blower installation is quick and
simple.

Optional Wall Thermostat

REMOVE THE BLUE JUMPER BETWEEN TH & TPTH SCREWS ON THE GAS VALVE.

The optional wall thermostat will automatically keep your room at an even temperature. You need to choose a
convenient location for the thermostat. Remember that it should be at least 10 feet from the stove and away
from direct radiation of the fire. Run the correct gauge wire (see table) from the valve to the thermostat and
wire as shown in the diagram.

DISTANCE

DIAMETRE

20

pi 18GA

30

pi 16GA

40 pi

14 GA

50pi 12GA

To use your ULTRA FLAME using the wall thermostat, follow the lighting procedure and set the gas control to
the ON position. Simply set your wall thermostat to a comfortable temperature and the stove will do the rest.

This manual is related to the following products: