ULTRA FLAME DIRECT VENT GAS STOVE

15

11. Install the vent casing and the cover in place

12. Seal around the terminal to prevent water leakage into the house

13. Seal around the 8 in. pipe to prevent cold air to get into the house.

14. Seal around the cover slots to avoid water infiltration into the vent terminal;

15. Insert spring spacers onto the 4 in. flexible pipe;

Use all necessary rigid sections to meet your specific needs. Fix 8 in. pipes together with metal screws;

16. Put some high temp silicone

on the stove’s 5 in. flange.
Insert the 5’’ x 4’’ reducer
(17) on the stove flange. Slip
one locking band (2) on the 4
in. pipe and secure it to the
reducer. Make sure seal is
perfect.

17. Fix the 8 in. pipe to the stove

with three metal screws.

18. Fix Seal around the 8 in. pipe

to prevent cold air to get into
the house. your stove to the
floor ;

19. Installation is now complete.

5" LOCKING BAND

SCREWS

5" FLEXIBLE FLUE PIPE

8"RIGID A