2
The CXL-50T is an optional transformer kit for the MA60/MA60
MEDIA
, to permit the
MA60/MA60
MEDIA
to directly drive 100 V, 70 V or 50 V-line loudspeaker systems. The
transformer is rated at 50 W output, and is mounted internally. The outputs are available
on a 4-pin 5 mm-pitch screw-terminal connector which occupies the hole (shown
below) in the rear panel normally covered by a blanking plate.
CXL-50T Connector
Introduction
Fitting the CXL-50T transformer kit
The transformer kit comprises the following items:
•
CXL-50T toroidal transformer, terminated on PCB-mounted 4-pin
connector
•
M6 countersunk-head fixing bolt
•
Safety cover
•
2 x M3 hex pillars
•
2 x M3 x 6 screws
•
Mating 4-pin connector
•
2 x cable ties
Proceed as follows:
1. Disconnect the MA60/MA60
MEDIA
from AC mains.
2. Take the top panel off by removing the eight M3 screws (six on the top panel
itself; two through the fornt panel) securing it.
3. Turn the unit upside down, and remove the plastic blanking plug from the M6
hole in the base of the unit. (The hole is in the centre of the chassis, about 8 mm
behind the front panel.) Insert the M6 fixing bolt supplied with the kit through the
hole.