BUILT IN DIMENSION FOR OVEN WITH DOOR THICKNESS OF

20mm (dim B)

(dim B)

4. When installing multipurpose ovens install the s shown in

figure nº6.

A. The support runner must be removed

B. Spacing of 75-90 mm between the wall and the rear part of

the support shelf and the base of the cupboard

C. Base

D. False box front to be assembled

Fig. 7: Ventilation and gap requirements for the installation of e

simple electric oven in a standard cooking unit.

Minimum ventilation requirements for upper, base and support

shelves for the rear part of the unit.

A. Rear panel

B. Storage space

C. Remove the rear part

of this section

D. Real panel

E. Storage space

F. Base

G. Minimum ventilation gap 80 cm

2

Fig. 8: Ventilation and gap requirements for the installation of a

simple electric oven in an upper cupboard.

ELECTRICAL CONNECTION

Before connecting the appliance, check that the voltage

marked on the specifications plate coincides with the voltage

of the electricity network.

The NICEIC register is recommended for electrical installa-

tions.

WARNING – THIS APPLIANCE MUST BE EARTHED

This appliance must be wired to a 13 A bipolar automatic

switch with protected socket, which has a 3 mm separation

between contacts and is placed in an easily accessible place

next to the appliance.

IMPORTANT

The conductors of the network power supply lead are coded

by colours are follows:

Green and yellow -Earth

Blue - Neutral

Brown - Live

• The green and yellow conductor must be connected to the

terminal marked “E” or with the symbol of the earth or which

is green and yellow.

• The blue conductor must be connected to the terminal

marked “N”.

• The brown conductor must be connected to the terminal

marked “L”.

• The lead must not reach a temperature higher than 50 ºC

above the ambient temperature at any point.

• If the power lead is damaged, it must be replaced by a spe-

cial lead or unit supplied by the manufacturer or it after-sales

service.