6) no record picture, Troubleshooting guide – Daewoo DVQ-13H1FC User Manual
Page 32
31
TROUBLESHOOTING GUIDE
3-6) NO RECORD PICTURE
Check the waveform of ICY01 #40
NG : GO to the figure
2-1 (TV PART)
OK : GO to the figure m
ICY01
VCR Y/C
LA71550M
XCS01
32KHz
Check
the crystal
Check
the voltage
ICS01
TIMER/
SYSCON
#65 #67
XS02
16MHz
#35
#36
#38
#39
#37
#34
RESET
Vcc(5V)
#98
#99
Vcc(5V)
Vcc(5V)
Check
the waveform
Check
the voltage
(5V)
REC Y
SCLK
SDATA
Check
the crystal
#16 #17
Check
SCL/SDA signal
IZ01
PREAMP
LA70001
#19
#17 #16
#9
#5
If REC Y/C no signal,
then change the ICY01.
2HEAD DRUM
#58
#56
#39
#11
Y Vcc
SW Vcc
CCD Vcc
C Vcc
#5
#19
C-SYNC
Check
the waveform
#4
#11
REC H
VH SW Pulse
#15
#20
#18
Check
waveform(30Hz)
Check
voltage
Vcc
Check
the voltage
(5V)
#13
Check
waveform
#31
#32
#9
#10
#94
#95
CTL
HEAD
CTL(+)
CTL(-)
Check
the waveform
(30Hz)
REC C
#2
#10
Check
the waveform
If REC no signal,
then change the IZ01.
#99
#97
C-rotary pulse
m
VH SW Pulse