Troubleshooting, Instructions for the installer – Caple C742G User Manual
Page 5

5
The Burners
The burner caps and crowns can be removed for cleaning. Wash the burner caps and crowns using hot soapy water, and remove marks
with a mild paste cleaner. A well moistened soap steel wool pad can be used with caution, if the marks are particularly difficult to remove.
After cleaning, be sure to wipe dry with a soft cloth.
Ignition electrode
The electric ignition is obtained through a ceramic "electrode" and a metal electrode. Keep these components very clean, to avoid lighting
difficulties, and check that the burner crown holes are not obstructed.
Thermocouple
The thermocouple is very crucial for cutting gas supply in case of flame out during cooking, be sure to keep them in very clean condition.
Troubleshooting
Problem
• There is no spark when lighting the gas
Corrective action
• Check that the unit is plugged in and the electrical supply is
switched on
• Check the mains fuse has not blown
• Check the burner cap and crown have been replaced correctly, e.g.
after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner crown is clear of
food particles.
• Check the burner cap and crown have been replaced correctly, e.g.
after cleaning.
Instructions for the Installer
Overall dimensions
Width: 590mm Depth: 510mm (For tempered glass models)
Width: 590mm Depth: 500mm (For other models)
Cut out dimensions
Width: 553mm Depth: 473mm
Technical Data
Burner configuration
NG
LPG
Injector Dia. (mm)
kW
Injector Dia. (mm)
kW
Gas category
I2H(20)/ I2E(20)/ I2E+
I2Lw
I2Ls
I3B/P(30)/ I3+
I3B/P(37)
I3B/P(50)
Wok burner
1.38
1.48
1.95
3.3
0.92
0.86
0.84
3.3 (241g/h)
Rapid burner
1.18
1.2
1.47
2.5
0.80
0.72
0.70
2.5 (182.5 g/h)
Semi
rapid
burner
0.92
1.0
1.23
1.5
0.63
0.58
0.57
1.5 (109.5 g/h)
Auxiliary
burner
0.75
0.86
1.0
1.0
0.53
0.49
0.45
1.0 (73 g/h)