Electricity supply
Once a satisfactory location has been established, the electrical supply to the appliance must
be arranged.
The mains voltage must correspond to that which is specified on the data plate.
The supply should be from a 30 amp fused spur, with an isolator switch installed above the
work surface and to one side of the unit in case of emergency. The isolator switch must have
woking contacts separated by 3mm.
This installation must be carried out in accordance with current I.E.E. Wiring Regulations and
Building Regulations (Part P).
The mains supply cable from the isolator to the unit must be rated for the maximum power
consumed by the unit (also specified on the data plate).
The supply cable must be long enough to allow for servicing the appliance.
The supply cable must be routed away from hot surfaces