ELECTRICAL CONNECTIONS
Before connecting the oven to the mains power supply, make sure that:
- The supply voltage corresponds to the specifications on the data plate on the front of
the oven.
- The mains supply has an efficient earth (ground) connection complying with all
applicable laws and regulations. Correct earthing (grounding) is a legal requirement. If
the appliance is not pre-fitted with a power cable and/or plug, use only suitable cables
and plugs capable of handling the power specified on the appliance’s data plate and
capable of resisting heat. The power cable should never reach a temperature 50
° C
above ambient temperature at any point along its length. If the appliance is to be
connected directly to mains terminals, fit a switch with minimum aperture of 3 mm
between the contacts. make sure that the switch is of sufficient capacity for the power
specified on the appliance’s data plate, and compliant with applicable regulations. The
switch must not break the yellow-green earth wire. The socket or switch must be easily
reachable with the oven fully installed.
*
CABLE TYPES AND DIAMETERS
230V H05RRF 3 x 1,5 mm
2
*
H05RN-F
400V 3N
*5 x 1,5 mm
2
400V 2N
*4 x 2,5 mm
2
230V 3
*4 x 2,5 mm
2
230V
*3 x 4 mm
2
N.B. The manufacturer declines all responsibility for damage or injury if the above