beautypg.com

Adjusting of the minimum of the top burners – Caple CR9205 User Manual

Page 18

background image

18

Adjusting of the minimum of the top burners

In the minimum position the flame must have a length of about 4 mm and must remain
lit even with a quick turn from the maximum position to that of minimum.

The flame adjustment is done in the following way:

– Turn on the burner

– Turn the tap to the MINIMUM position

– Take off the knob

– With a thin screwdriver turn the screw F until adjustment is correct (fig. 3.6).

Normally for LPG, the regulation screw is tightened up.

F

Fig. 3.6