beautypg.com

Provision for ventilation – Caple CR9205 User Manual

Page 12

background image

12

Provision for ventilation

– The appliance should be installed into a room or space with an air supply in accor-

dance with BS 5440-2: 2000.

– For rooms with a volume of less than 5 m

3

- permanent ventilation of 100 cm

2

free

area will be required.

– For rooms with a volume of between 5 m

3

and 10 m

3

a permanent ventilation of

50 cm

2

free area will be required unless the room has a door which opens directly

to the outside air in which case no permanent ventilation is required.

– For rooms with a volume greater than 10 m

3

- no permanent ventilation is required.

NB. Regardless of room size, all rooms containing the appliance must have direct

access to the outside air via an openable window or equivalent.

– Where there are other fuel burning appliances in the same room, BS 5440-2: 2000

should be consulted to determine the correct amount of free area ventilation require-
ments.

– The above requirements allow also for use of a gas oven and grill but if there are

other gas burning appliances in the same room, consult a qualified engineer.