background image

Flame faulty in

Flame correct

Flame with excess

primary air

primary air

long, yellow and trembling

clear interior blue cone

short and sharp

too blue interior cone

tending to detach

CAUSE

air regulating tube,

correct distance

air regulating tube,

too closed

of the tube

too open

Adjusting of the minimum of the top burners

Considering that in the minimum position the flame must have a length of about 4 mm
and must remain lit even with a brusque passage from the maximum position to that of
minimum.
The flame adjustment is done in the following way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a small flat screwdriver turn the screw inside the tap rod to the correct regulation

(fig. 3.5).

Normally for LPG, tighten up the regulation screw.

Fig. 3.5