beautypg.com

Conversion to lpg, Conversion procedure – Caple CR910SS User Manual

Page 12

background image

12

Conversion to LPG

J

J

Fig. 3.3

Fig. 3.4

Conversion procedure

Injectors replacement

Select the injectors to be replaced
according to the “Table for the choice of
the injectors” (page 13).

To replace the injectors proceed as fol-
lows:

- Remove pan supports and burners

from the cooktop.

- Using a wrench, substitute the nozzle

injectors “J” (fig. 3.3, 3.4) with those
most suitable for the kind of gas for
which it is to be used.

The burners are conceived in such
a way so as not to require the regu-
lation of the primary air.

Minimum burner setting
adjustment

In the minimum position the flame must
have a length of about 4 mm and must
remain lit even when turned quickly
from the maximum position to mini-
mum.

The flame adjustment is done in the
following way:

- Turn on the burner

- Turn the tap to the MINIMUM position

- Take off the knob

- With a small flat screwdriver turn the

screw inside the tap rod to the cor-
rect regulation (fig. 3.5).

Normally for G30/G31, the regulation
screw is tightened up.

Fig. 3.5