Caple RBR1A User Manual
Page 4

For equipment with ISOBUTANE (R600a)
Ƹ
Isobutane is a natural gas that doesn't affect the environment, but it is inflammable. It is therefore indispensable to
check that the cooling circuit tubing is not damaged before connecting the equipment to the mains.
- For every 8 g of cooling fluid, the installation location must have a minimum volume of 1 cubic metre. The amount of
cooling fluid in the appliance is indicated on the technical data plate inside the refrigerator.
- Leakage of cooling fluid: avoid naked flames or other sources of ignition at the seat of the leakage.
A
A
INSTALLATION
In order to avoid damage to persons or property, the equipment should be installed by two persons.
In the event of damage to the equipment during transport, immediately inform the supplier before proceeding to
installation. The equipment must be placed in a dry, well ventilated position.
The equipment must be installed on a flat, stable surface, using the adjustable feet if necessary and following the
instructions provided inside the product.
In fitting the equipment inside the unit make sure you don't squash the power cable.
Air inflow to and outflow from the equipment must be ensured by means of an aperture in the skirting board and a
vertical slit in the rear of the unit.
Minimum transverse section of aperture in skirting board and slit: 250 cm
2
.
Ambient temperature has a considerable influence on energy consumption, so the equipment should not be exposed
to direct sunlight or placed by heat sources such as radiators, heaters, cookers, etc. If necessary install insulation
panelling against the sides of the unit.
Check the climate classification on the technical data plate inside the equipment, on the left hand side.
"SN" (operates at ambient temperatures between) +10° C and +32° C
"N"
(operates at ambient temperatures between) +16° C and +32° C
"ST" (operates at ambient temperatures between) +16° C and +38° C
"T"
(operates at ambient temperatures between) +18° C and +43° C
Warning!
It is important to ensure access to the equipment's power outlet in the wall, so that the plug can be removed if
necessary.
If this isn't possible, connect the equipment to the mains via a double pole switch with a contact opening distance of at
least 3 mm in an accessible position.
▵
ELECTRICAL CONNECTION
Connection of the equipment to a power outlet with an earth contact is required by law. For this reason the equipment
is provided with a plug with an earth wire to fit in an outlet of the same type. The manufacturer declines any liability for
damage to persons or property due to failure to observe this rule.
Check that the voltage indicated on the technical data plate inside the fridge on the left hand side is the same as that
of your mains supply.
Instructions for replacing internal light:
Disconnect the plug or switch off the main supply switch before changing the light. the new lamp must be of the same
wattage as the value indicated on the lamp shield (eg. max. 15 W).
4