GENERAL

Carefully read the following important information regarding

installation safety and maintenance. Keep this information

booklet accessible for further consultations.

The appliance has been designed for use in the filtering ver-

sion (air recirculation on the inside – Fig.1A).

SAFETY PRECAUTION

1. Take care when the cooker hood is operating simultane-

ously with an open fireplace or burner that depend on the air

in the environment and are supplied by other than electrical

energy, as the cooker hood removes the air from the environ-

ment which a burner or fireplace need for combustion. The

negative pressure in the environment must not exceed 4Pa

(4x10-5 bar). Provide adequate ventilation in the environment

for a safe operation of the cooker hood.

Follow the local laws applicable for external air evacuation.

Before connecting the model to the electrical supply:

- Check the data plate (positioned inside the appliance) to

ascertain that the voltage and power correspond to the

network and the socket is suitable. If in doubt ask a qualified

electrician.

- If the power supply cable is damaged, it must be replaced

with another cable or a special assembly, which may be

obtained direct from the manufacturer or from the Technical

Assistance Centre.

- This device must be connected to the supply network

through either a plug fused 3A or hardwired to a 2 fase spur

protected by 3A fuse.

2. Warning !

In certain circumstances electrical appliances may be

a danger.

A) Do not check the status of the filters while the cooker

hood is operating

B) Do not touch bulbs or adjacent areas, during or straight

after prolonged use of the lighting installation.

C) Flambè cooking is prohibited underneath the cooker

hood

D) Avoid free flame, as it is damaging for the filters and

a fire hazard

E) Constantly check food frying or the overheated oil may

become a fire hazard

F) Disconnect the electrical plug prior to any

maintenance.

G) This appliance is not intended for use by young children

or infirm persons without supervision

H) Young children should be supervised to ensure they do

not play with the appliance

I) There shall be adequate ventilation of the room when

the cookerhood is used at the same time as appliances

burning gas or other fuels

L) There is a risk of fire if cleaning is not carried out in

accordance with the instructions

This appliance conforms to the European Directive EC/2002/96,

Waste Electrical and Electronic Equipment (WEEE). By making

sure that this appliance is disposed of in a suitable manner,

the user is helping to prevent potential damage to the

environment or to public health.

The symbol on the product or on the accompanying

paperwork indicates that the appliance should not be treated

as domestic waste, but should be delivered to a suitable

electric and electronic appliance recycling collection point.

Follow local guidelines when disposing of waste. For more

information on the treatment, re-use and recycling of this

product, please contact your local authority, domestic waste

collection service or the shop where the appliance was

purchased.

INSTALLATION INSTRUCTIONS

Assembly and electrical connections must be carried out

by specialised personnel.

• Electric Connection

Note: Verify the data label placed inside the appliance:
- If the symbol DOES NOT appear on the plate, follow

the instructions concerning insulation class I.

Insulation class I

Warning:

This is a class I, appliance and must therefore be connected

to an effiecient earthing system.

The appliance must be connected to the electricity supply

as follows:

BROWN = L live wire

BLUE = N neutral

YELLOW / GREEN = earth

The neutral wire must be connected to the terminal with the N

symbol while the YELLOW / GREEN, wire must be connected

to the terminal by the earth symbol .

Warning:

When connecting the appliance to the electricity supply, make

sure that the mains socket has an earth connection.

After fitting the ducted cooker hood, make sure that the

electrical plug is in a position where it can be accessed

easily.

If the appliance is connected directly to the electricity supply,

an omnipolar switch with a minimum contact opening of

3 mm must be placed in between the two; its size must

be suitable for the load required and it must comply with

current legislation.

• If the hob is electric, gas, or induction, the minimum distance

between the same and the lower part of the hood must be

at least 65 cm.

If a connection tube composed of two parts is used, the upper

part must be placed outside the lower part.

Do not connect the cooker hood exhaust to the same conduc-

tor used to circulate hot air or for evacuating fumes from other

appliances generated by other than an electrical source.

Attention! This product is only supplied RECIRCULATING

version.

Hood installation

- Position the drill hole template on the ceiling making sure

that the arrow is positioned on the same side of the appli-

ENGLISH

GB

- 9 -