Venting installation instructions, Continued – Desa CHDV42NRA User Manual
Page 9
111906-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
WARNING: Do not recess vent termination into
any wall. This will cause a fire hazard.
6.
Noncombustible Exterior Wall:
Position the horizontal vent
cap in the center of the 8
1
/
2
" round hole and attach to the exte-
rior wall with four wood screws provided. Before attaching
the vent cap to exterior wall, run a bead of non-hardening mastic
(pliable sealant) around the outside edges to make a seal be-
tween it and the outside wall.
Note:
The four wood screws
provided should be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of sidings.
Combustible Exterior Wall:
For vinyl siding, stucco, or wood
exteriors, a siding standoff may be installed between the vent
cap and exterior wall. The siding standoff prevents excessive
heat from damaging the siding materials. Siding material must
be cut to accommodate standoff. Bolt the vent cap to the stand-
off. Apply non-hardening mastic around outside edge of stand-
off. Position the standoff/cap assembly in the center of the
10
3
/
4
" square hole and attach to exterior wall with wood
screws provided (see Figure 11). The siding standoff must sit
flush against the exterior fascia material.
7.
Combustible Exterior Wall Only:
Slide the wall firestop over
the vent pipe before connecting horizontal run to vent cap (see
Figure 12).
8.
Carefully move fireplace, with vent assembly attached, toward
wall and insert vent pipe into horizontal termination. The pipe
overlap should be a minimum of 1
1
/
4
". Fasten all vent pipe
connections (except vent cap) with screws provided.
VENTING INSTALLATION
INSTRUCTIONS
Continued
VENTING INSTALLATION INSTRUCTIONS
Installation Planning (Cont.)
Figure 10 - Installing Horizontal Vent Cap (Noncombustible
Exterior)
Apply Mastic to
All Four Sides
Figure 11 - Installing Siding Standoff (Combustible Exterior)
Vent Cap
(Horizontal
Termination)
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe
Screw
Cut Siding Away
to Fit Standoff
Wood Screw
Screws
Standoff
Vent Cap
Apply Mastic
to All Four Sides
Wood Screw
Vent Cap