 4 1200 
 5 600 
 6 300 
 7 110 
 
Unit Identification Code 
The next two front panel thumbwheel switches, 
Channels 3 and 4, are used to program the Unit 
Identification Code. In multiple unit remote 
configurations (Mode 4), this value can be any 
number from 00 - 99, but care must be taken to 
insure that all units have a different code. In a 
single unit system (Mode 3), Channels 3 and 4 
have no effect. 
 
Example of Switch Setting 
With the thumbwheel switches set to 4101000 the 
VS8x8 is configured for Mode 4 operation at 9600 
Baud with an ID of 01. 
 
Storing Mode Settings 
Storing the configuration information into internal 
EEPROM is accomplished by first setting the 
front panel thumbwheel switches, (Channel 1-4) 
to the desired settings. The unit is then powered 
up while depressing the front panel LOAD 
pushbutton. Upon power up, the internal 
microprocessor detects the depression of the 
LOAD switch and then programs the internal 
EEPROM memory with the selected values. The 
unit will flash the front panel SET LED for a few 
seconds to indicate that it is programming the 
system EEPROM, and will then enter that 
VS8x8 Crosspoint Video Switch