12 ......... electrical component chart, Wiring diagram / bug-5100-f dc iii drive unit, Vacuum support kit – BUG-O Systems CIR-O User Manual
Page 12: Electrical component chart

12
WIRING DIAGRAM / BUG-5100-F DC III
DRIVE UNIT
120 (42) VAC
INPUT
240 VAC
INPUT
CB
BLK
BLK
WHT
A
D
V
WHT
T
TAN
TAN
RED
12 VAC
YEL
DK. BLU
DK. BLU
WHT/BLU
P
1
2
3
4
5
6
7
8
POT
M-
M+
AC
F
S
M
PK
GY
RED
BLK
CB
BLK
A
WHT
D
BLK
T
12 VAC
ELECTRICAL COMPONENT CHART
ITEM DESCRIPTION
BUG-5100-F
BUG-5102-F
BUG-5104-F
120 VAC
240 VAC
42 VAC
A
Power Cord
BUG-9445
GOF-3115
BUG-9442
CB
Circuit Breaker
BUG-2923 (.7A)
BUG-2952 (.5A)
BUG-2933 (2A)
D
Pilot Light
BUG-1415
BUG-1428
BUG-1427
V
Volt Trap
BUG-1393
BUG-1563
BUG-1393
T
Transformer
BUG-9675
GOF-3112
BUG-1466
M
Gear Motor
* BUG-1550 (150:1)
F
Precision Speed Control
BUG-1725
S
Toggle Switch
BUG-2255
P
Potentiometer Control
BUG-9686
* BUG-1600 (50:1)
BUG-1595 (100:1)
PART NUMBER
13
CON-1006 VACUUM SUPPORT KIT can be mounted on any CIR-0 or CON-0
ring base with standard CON-1003 legs. Vacuum pump kits are available for
operation on 120 VAC [ARV-2020] or 240 VAC [ARV-2030]
Each vacuum cup holds 50 lbs (22 kg).
(Dirt and scale block vacuum lines; blow-out when clogged).
Keep flame 4'' (100 mm) away from cups when burning or welding. Silicone
vacuum cups will withstand a temperature of 600°F (318° C).
ITEM PART NO.
DESCRIPTION
1 ARV-1004-14
Hose 14" (355 mm)
2 ARV-1005
Hose Clamp
3 ARV-1013
Male Quick Connector 1/4 NPT
4 ARV-2020
Vacuum Pump Kit (I 20 VAC/60 Hz/1 Ph)
ARV-2030
Vacuum Pump Kit (220 VAC/60 Hz/1 Ph)
5 ARV-1034
Choke Nipple
6 ARV-1107
3/8'' Hose Barb 1/4 NPT
7 ARV-1109
Protective Cap
8 ARV-1116
Vacuum Cup (Silicone) 50 lbs. (22 kg)
9 CON-1007
Vacuum Leg
10 CON-1020
Double Swivel Clamp Assembly
Vacuum Pump is not included in CON-1006 Vacuum Support Kit.
VACUUM SUPPORT KIT
10 1 2
9 6
7
8 4
5
3