INTRODUCTION:

The Programmable Stiffener Welder mechanizes two wire feeders to weld various types of stiffeners on

one or both sides simultaneously. The unit features independent wire feeder controls for voltage, wire

feed speed, cold wire jog and gas purge. When intermittent stitch welding is required the unit features

programmable control of weld length and travel speed, skip length, reverse drive crater fill, pre-weld and

post-weld gas purge times. Please see the Technical Data information in this manual for unit capacities.

SETUP & OPERATION:

(Refer to the Controls Sections pg. 6, 7 and Major Components section pg. 10, 11 in this manual.)

1. Center the unit over the work piece. Connect welding cables and wire feeder control cables for each

feeder to the welding power sources. Connect the welding gas hoses to each

Flow Meter/Valve

Assembly. Plug the unit into an available 110 VAC 50/60 Hz power source.

2. Turn power “ON” to both welding power sources. Turn power “ON” to the control panel by toggling

the “

ON/OFF” switch on the upper rear left hand side of the control box to the “ON” position. Turn

ON” power to both feeders by toggling the feeder “ON/OFF” switches located on the front lower left

and right of the control box to the “

ON” position.

NOTE: Ensure that the Emergency Stop Switch located on the top of the control box is in the

released position or no power will be supplied to the unit.

3. Adjust the Capture Wheel Assemblies so that they contact the side of the work. Swing the Drive

Unit into position against the work piece and engage the Drive Latch and tighten to ensure constant

pressure on the work piece between the Drive Assembly, Work Piece and Capture Wheel Assemblies.

NOTE: Move the unit forward and reverse using the Travel Manual Jog Switch located on the front

bottom center of the control box to ensure proper tension has been applied by the

Drive Latch to

move the unit smoothly along the work piece.

4. Align the left and right Corner Followers and welding guns for the desired weld placement. The

Corner Followers can be adjusted up, down, in and out to achieve the placement you desire. The

Corner Followers are also equipped with a gun angle adjustment knob to achieve the desired torch

angle. Purge the shield gas to each welding gun by pressing the

Shield Gas Purge button located

on the left and right sides of the control panel for each

Flow Meter/Valve Assembly.

5. Set all welding parameters. Each wire feeder’s wire speed and voltage are set independently from

each other utilizing the controls to the left and right of the soft touch

Programming Center located

on the control panel. All other welding parameters are set using the soft touch

Programming Center.

Please refer to the controls section of the manual.

6. When you are ready to begin your weld cycle press the Weld Cycle Start button located on the

control panel below the soft touch

Programming Center. To stop the weld cycle press the Weld

Cycle Stop button.

NOTE:

In case of an emergency press the

Emergency Stop switch located on the top of the control

box to kill all power to the unit including the weld cycle. Once the

Emergency Stop switch is returned

to the released position you will need to press the