Arv-1036 intermediate vac support bar – BUG-O Systems DC IV v.2 User Manual
Page 17

17
NOTE: Keep flame or arc at least 4" (100 mm) away from vacuum cups.
Vacuum Cups can be used on preheated material to 600
0
F (318
0
C). Each
vacuum cup exerts a maximum pull of 50 lbs. (22.5 kg).
ARV-1036 VACUUM SUPPORT KIT / PARTS LIST
ITEM QTY PART NO. DESCRIPTION
1
2
ARR-9008
Spacer Tube
2
2
ARV-1034
Choke Nipple
3
2
ARV-1107
3/8 Hose Barb x 1/4 NPT-M
4
2
ARV-1109
Protective Cap
5
1
ARV-1111
Support Bar
6
2
ARV-1116
Vacuum Cup (Silicone)
7
2
FAS-0252
Rnd Hd Scr 1/4-20 x 1/4
8
2
FAS-2372
Hex Hd Cap Scr 5/16-18 X 1-1/4
ARV-1036 VACUUM SUPPORT KIT / EXPLODED VIEW
VACUUM CUPS are used for mounting the rail to the workpiece
when magnet bars will not hold. EXAMPLE: Stainless steel or
nonferrous surfaces. The surface must be smooth and nonporous.
Each vacuum bar is fitted with two (2) cups and will exert a
maximum pull of 100 lbs. (45 kg).
ARV-1036 INTERMEDIATE VAC SUPPORT BAR
8
1
3
4
3
4
5
7
2
6