beautypg.com

Cwo-1805 wire feeder controls, cont’d – BUG-O Systems CW-18 User Manual

Page 9

background image

9

NOTE: For further information refer to Lincoln Electric NA-3 Operator’s Manual.

A. AMMETER

Indicates current only while welding.

B. CIRCUIT BREAKER

Protects the circuit from severe wire feed motor overload and short circuits. Press to reset.

Locate and correct the cause for overload.

C. VOLTMETER (Standard)

Indicated welding voltage only while welding. Also indicates OCV below 60 volts.

D. START

Push-button begins the welding cycle

E. STOP

Push-button initiates the stopping cycle at the end of the weld.

F. INCH UP & INCH DOWN

Press to inch electrode at the speed set by “Inch Speed” control on inner panel.

G. CURRENT CONTROL

Adjusts wire feed speed to control welding current.

H. TRAVEL

Turn to “Off” for no travel; “Hand Travel” for travel without welding; “Automatic Travel” for welding

operations. Speed and direction of travel are controlled by the travel mechanisms control.

I. VOLTAGE CONTROL

Adjust arc volts by controlling power source output voltage.

J. CONTROL POWER

Turns input control power “On” and “Off”. Also used as an emergency “Off” in case of malfunction.

*For further information on Wire Feeder and controls, refer to Wire Feeder Operators Manual.

CWO-1805 WIRE FEEDER CONTROLS, CONT’D.