PREVENTATIVE MAINTENANCE / CW-18 CIRCLE WELDER, CONT’D.
Refer to CW-18 Exploded View & Parts List. (Pg. 12-13)
CW-18 Collector Item #3:
The collector ring should be sanded once a year. If the collector ring is pitted too badly it should be
replaced. Inspect all wires coming out of the collector ring for cut or missing insulation. All wires should
be fastened to the center shaft with a nylon cable tie. Tighten four set screws if needed.
Weld Cable Inlet 4/0 Item #10:
Ensure that the cable is fastened tightly to the collector ring. Inspect the cable for cut or missing
insulation. Make sure the micarta insulation tube on the cable is in good condition. Replace the cable if
necessary.
Control Cables :
For all cables leading to the CWO-1805 Control Box, inspect the cable for cuts or missing insulation.
Ensure that the elbow connector is not damaged. Ensure that all terminal ends are snug. Replace cable
if necessary.
Solenoid Adaptor Kit (Optional):
Inspect for damage. Replace if necessary.