Mechanical installation, Power – BSS Audio BLU-10 Install Guide User Manual
Page 3
3
Mechanical Installation
The BLU-10 is designed to fit into a standard 3-gang US wall box. Screws are
provided to fix the unit in place.
Dimensions of the unit are shown below. The use of a metal wall box is
recommended to ensure that the installation meets necessary EMC standards.
170mm
6.69ins
57mm
2.24ins
123mm
4.84ins
26mm
1.02ins
31mm
1.22ins
45mm
1.77ins
Power
The BLU-10 requires 12-48V DC to be supplied externally. There are two ways to do
this:
Connect a suitable supply to the 12-48V DC connector, see diagram below,
or
the unit may be power via the Ethernet connector using IEEE802.3af Power Over
Ethernet (POE).
Typical mid-span ethernet powering devices are:
3Com® Power over Ethernet Single-Port Midspan Solution - p/n 3CNJPSE
3Com® Power over Ethernet Multiport Midspan Solution - p/n 3CNJPSE24
Ethernet switches with power over ethernet ports include:
3Com® SuperStack® 3 Switch 4400 PWR - p/n 3C17205
HP ProCurve Switch 2626-PWR - p/n J8164A#ABA