2 connection to measuring devices – Bronkhorst R Modules for Ex-proof applications User Manual
Page 13
BRONKHORST HIGH-TECH B.V.
Potmeters for controller parameter setting are accessible via holes in the rear panel.
Potmeter:
P6:
controls the valve quick start-up voltage. Set for optimum fast response behaviour from zero
setpoint. (optional)
P3:
(flow control only) Controls the output differentiating network. This determines the dynamic
response characteristic of the system.
P4:
(flow control only) Controls the D-action of the control circuit.
3.2 Connection to measuring devices
The instrument connector is a female sub-miniature 9-pin D-connector. The pin designation is according to the
Bronkhorst High-Tech B.V. standard for intrinsic safe instruments
pinnumber description
1
2
3
4
5
6
7
8
9
not connected
+ 15 - 20 mA/4 - 20 mA
not connected
not connected
not connected
not connected
-15 - 20 mA/4 - 20 mA
not connected
ground
The + and - current signal input is intended for loop powered transducers.
6
3
4
P
P
P
9.17.034
page 13