Problem/Symptom
Cause
Action/cure
Fill valve turns on/off without
toilet being flushed
Flush valve seal gasket is dirty
Inspect and clean flush valve seal gasket
Fill valve continuously running
Dirty fill valve seal
Shut off water supply. Open fill valve cap
and clean valve seal.
Poor flush
Water supply is not fully open
Open water supply valve
Toilet not flushing
Water supply vavle is closed
Open water supply valve
Push button is stuck
Tank lid is misaligned
Align the tank lid
Water supply pressure is too low
The minimum required supply pressure
is 20 psi. Consult your plumber.
Trapway is obstructed
Unclog trapway
Venting is obstructed
Clean venting pipes
Flush valve seal gasket is dirty
Inspect and clean flush valve seal gasket
1.
2.
3.
4.
5.
a)
a)
b)
a)
b)
c)
d)
a)
a)