beautypg.com

Alarm recording – Daewoo DV3K683DZ-SD User Manual

Page 13

background image

21

Time Lapse Video Cassette Recorder

20

Time Lapse Video Cassette Recorder

• Auto / 20sec / 30sec / 40sec / 01min / 02min / 3min /

5min / 10min / 15min / 20min / 25min / 30min :
Recording for the set duration. (min : minute)

• T.END : Records until the tape end is reached when

there is alarm trigger input.

Alarm Recording Counter Display

During alarm recording, “

” will be flashing on the

display panel.

The maximum display number of alarm triggers is “35”,
at the next alarm recording the counter will indicate
“00”.

Connecting to a Monitor for Normal Recording

• Alarm Counter Reset can

be performed by pressing
the CLEAR key in “Alarm
Time” of Initial Menu
screen.

Alarm Recording

Alarm Recording Setting

Alarm recording is performed when there is an input
(trigger) at the ALARM IN terminal, “

” is displayed

on the display panel.

1

Make all necessary connections.

2

Press the MENU, SHIFT

, SHIFT

buttons in

sequence to display the REC MODE SET menu .

3

Press the SHIFT

button until the arrow mark (

)

points to ALARM REC SET.

4

Press the SHIFT

button to display the ALARM REC

SET menu.

5

Press the SHIFT

button to select “YES” or “NO”.

• YES . . . .The alarm recording takes place when there is

alarm trigger input

• NO . . . . The alarm recording does not take place

6

Press the SHIFT

button to set the Alarm speed.

7

Press the SHIFT

button to select the desired

recording speed.

• 3H . . . 3-hour mode recording
• 6H . . . 6-hour mode recording
• 18H . . 18-hour mode recording
• 30H . . 30-hour mode recording

8

Press the SHIFT

button to set the alarm duration.

9

Press the SHIFT

button to select the desired

recording duration.

• Auto : Records as long as the alarm signal is being

input. (Minimum 2 minutes is recorded.)

• During alarm recording all

buttons are disabled
except the STOP button. If
the STOP button is
pressed, the alarm
recording will stop.

• If an alarm trigger is

received while alarm
recording is in progress,
the recording duration for
the second alarm will be
calculated from that point.

• When there is a power

loss during alarm
recording, if the power is
restored within the
recording set duration,
alarm recording will
continue.

• When you select ‘Alarm

Duration’ as 20sec,
30sec, 40sec or 1min,
alarm search error may
happen. Therefore confirm
it in ‘Alarm TIme’ menu
and scan it.