• During filling, leave the humidification discs in the tub. Fill the tub with fresh, cold tap water at most up

to the lower edge of the “MAX” marking (7.2 l) on the inside of the tub. The most straightforward way to
do so is to use a large container free of limescale and impurities (water can, jug). Use only fresh, cold tap
water. For optimum humidification output, we recommend filling the tub with water up to the “OPT” mark
(3.6 l).

• Place the upper cover with integrated fan unit on the tub. If the upper cover cannot be placed precisely

onto the tub, turn the upper cover around by 180 degrees. This is a design feature and ensures that the
fill level sensor contacts touch each other. Never use force to place the upper cover on the tub. Otherwise
the device will be damaged.

Important

• Do not add any essential oils or fragrances. If other additives are used, the plastic material may

become discoloured and damaged.

Ensure the water level in the tub with inserted humidification discs never exceeds the lower edge
of the “MAX” marking on the inside of the tub.

Tip:

The addition of a small volume of conventional washing-up liquid (e.g. 1 drop) breaks the water
surface tension and increases evaporation output.

Positioning the device

• Place the humidifier on a firm, even, water-resistant surface.
• Position the air washer in the vicinity of a heater to improve evaporation, in particular in large rooms

(do not exceed a max. temperature of 50 °C). Always ensure that the air inlet and air outlet remain clear
and that the air flows freely.

• Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard. You can clamp

the mains cable in the vertical ridge on the rear of the tub and lead it downwards.

6. Operation

Switch on the device using the On/off button

in the centre of the upper cover. The display lights up, shows

fan level 0 and the water fill level.
Select the fan speed using the fan button in the centre of the upper side.

Graphic displayed

Fan level

Level 0, standby – fan off

Level 1, low

Level 2, medium

Level 3, maximum

The water level gauge indicates the tub fill level:

Graphic displayed

Fill level

approx. 4.3 l to 7.25 l

Approx. 2.5 l to 4.3 l

Approx. 0.5 l to 2.5 l