4.2.1.5 EverMore Binary Input Message 0x8F: Set Operating Mode
Purpose
Sets the navigation update rate and receiver-operating mode. The receiver-operating mode
can be set to one of the following:
1. Normal full power mode without 1PPS output synchronized.
2. Power saving mode without 1PPS out synchronized.
3. Normal full-power mode with 1PPS output synchronized.
With Navigation Update Rate set to n, measurement is taken and navigation solution is
computed every n seconds. When power saving mode is selected, the RF/GPSBBP On Time
field is also referenced.
Format
Byte #
Contents
Range
Size
Scale Unit
1
Message ID = 0x8F
Unsigned byte
2
Receiver Operating Mode
0 = Normal Mode
1 = Power Saving
2 = Normal Mode
with 1PPS
0 ~ 2
Unsigned byte
3
Navigation Update Rate
1 ~ 10
Unsigned byte
1 / Hz
4
RF/GPSBBP On Time
0=Power on 160ms
1=Power on 220ms
2=Power on 280ms
3=Power on 340ms
4=Power on 400ms
0 ~ 4
Unsigned byte
Note: Instead of software control, the 1PPS function can be also enabled through hardware
control. There are two I/O pins used for 1PPS function.