beautypg.com

Deluo TRISTAR25 User Manual

Page 23

background image

Deluo Electronics http://www.deluo.com

23

4.2.1.5 EverMore Binary Input Message 0x8F: Set Operating Mode

Purpose

Sets the navigation update rate and receiver-operating mode. The receiver-operating mode

can be set to one of the following:

1. Normal full power mode without 1PPS output synchronized.

2. Power saving mode without 1PPS out synchronized.

3. Normal full-power mode with 1PPS output synchronized.

With Navigation Update Rate set to n, measurement is taken and navigation solution is

computed every n seconds. When power saving mode is selected, the RF/GPSBBP On Time

field is also referenced.


Format

Byte #

Contents

Range

Size

Scale Unit

1

Message ID = 0x8F

Unsigned byte

2

Receiver Operating Mode

0 = Normal Mode
1 = Power Saving
2 = Normal Mode

with 1PPS

0 ~ 2

Unsigned byte

3

Navigation Update Rate

1 ~ 10

Unsigned byte

1 / Hz

4

RF/GPSBBP On Time

0=Power on 160ms
1=Power on 220ms
2=Power on 280ms
3=Power on 340ms
4=Power on 400ms

0 ~ 4

Unsigned byte

Note: Instead of software control, the 1PPS function can be also enabled through hardware

control. There are two I/O pins used for 1PPS function.