Assembly hole for the m6331 built-in panel, Mechanical features, Fittings – BECKHOFF M6330 User Manual
Page 3: General electrical properties
INDUSTRIE
INDUSTRIE
INDUSTRIE
INDUSTRIE ELEKTRONIK
ELEKTRONIK
ELEKTRONIK
ELEKTRONIK
Eiserstraße 5 / D-33415 Verl / Phone 05246/963-0 / Fax 05246/963-149
M6330 Control Unit
Page 3
Mechanical Features
- External dimensions of aluminium diecast housing: 240 * 160 * 117 mm, type ROLEC
- Built-in panel: External dimensions of built-in plate: 243 * 134 mm
Hole required: 216 * 108 mm, page 2
- If the rear of the device will no longer be accessible after assembly, making it mechanically necessary to
plug in the connecting strip before the built-in panel is fitted, the hole needs to be 226 * 108 mm large.
An appropriate drawing can be requested.
- Mounting depth: 78 mm under the front panel
- Key arrangement: see page 1
- Protection type: for version mounted in housing, IP65 on all sides
for built-in panel, IP65 to the front
- Fitting to customer-specific housings is a possible option
Fittings
- All actuators in the SCHLEGEL OKTRON range that can be combined with normal contact makers can be
used
- Key cap colours optionally white, green, yellow, blue or red
- Marking with standard symbols using ready-made labelling inserts or blank inserts for special signs
General Electrical Properties
- 32 electro-mechanical keys from the SCHLEGEL OKTRON series, illuminated, pre-wired as make contact.
The upper 8 keys are optionally connected to a terminal strip for 24 V wiring. They are pre-wired as
changeover contacts. One of these keys is wired specially (to a single-terminal connection) for an
emergency off function
In 24 V applications the 8 switches are electrically galvanically isolated from the electronics
- Power supply 24 V DC, 400 mA + 30 mA per lamp
Terminal no.
Function
Terminal no.
Function
A/B 1
13
from emergency off switch /
switch B 100
A/B 9
14
from switch A / B 102
A/B 2
14
from emergency off switch /
switch B 100
A/B 10
22
from switch A / B 102
A/B 3
21
from emergency off switch /
switch B 100
A/B 11
13/21 from switch A / B 103
A/B 4
22
from emergency off switch /
switch B 100
A/B 12
14
from switch A / B 103
A/B 5
13/21 from switch A / B 101
A/B 13
22
from switch A / B 103
A/B 6
14
from switch A / B 101
A/B 14
0 V
A/B 7
22
from switch A / B 101
A/B 15
+24 V power supply
A/B 8
13/21 from switch A / B 102