BECKHOFF DK9222-0909-0005 User Manual
Page 3

XFC
XFC technology oversampling
Application Note DK9222-0909-0005
communication cycle is divided into 10 intervals. The change of state at the input or output is determined with a precision of
100 µs.
1
2
3
4
5
6
7
8
9
100 μs sample time
10
samples
1 ms cycle time
Fig. 2: Cycle time vs. sample time
Different oversample frequencies can be set depending on the terminal. As a rule, the configurable frequency does not depend
on the bus speed, but on the signal processing within the terminal. Digital input and output terminals currently enable
resolutions of up to 1
µs, with analog signals the smallest possible interval is 10
µs. Even for moderate communication cycles
with only 1 ms, digital signal acquisition is possible with a 1000
th
of the time, analog with a 100
th
.
New Automation Technology
Beckhoff
For application notes see disclaimer on the last page
- Bus Terminal System (19 pages)
- EP-xxxx-xxxx (19 pages)
- BK2000 (30 pages)
- LC3100 (67 pages)
- BK4000 (28 pages)
- BK3xx0 (95 pages)
- BK5000 (12 pages)
- LC5200 (32 pages)
- BK7000 (29 pages)
- BK7500 (32 pages)
- BK7300 (40 pages)
- BK8100 (26 pages)
- BC2000 (28 pages)
- BC3100 (51 pages)
- BC7300 (48 pages)
- BC8100 (36 pages)
- BC3150 (112 pages)
- KL1012 (2 pages)
- KL1114 (2 pages)
- KL1164 (1 page)
- KL1232-xxxx (4 pages)
- KL1501 (19 pages)
- KL1512 (15 pages)
- KL2521-0024 (18 pages)
- KL2512 (21 pages)
- KL2612 (4 pages)
- KL2622 (9 pages)
- KL3062 (24 pages)
- KL3064 (20 pages)
- KL4132 (19 pages)
- KL4034 (25 pages)
- KL3302 (23 pages)
- KL3351 (18 pages)
- KS3681 (43 pages)
- KL4112 (18 pages)
- KL5001 (16 pages)
- KL5051 (17 pages)
- KL5101-0012 (21 pages)
- KS5111-0000 (21 pages)
- KL5121 (19 pages)
- KL6021 (20 pages)
- KL6051 (17 pages)
- Z1000 (2 pages)
- KL6071 (12 pages)
- Z1003 (2 pages)