Magnetic Encoder System (MES)
Page 2
for Linear Motors AL2xxx
MES
Signal
color
SIN +
green
SIN -
yellow
COS +
blue
COS -
red
+ 5 VDC
brown
+ 5 V sense
pink
GND
white
GND sense
grey
Link between 4 - 12 and 2 - 10!
Necessary coupling connector: ZS4000-2051 (Service Pack). By using this standard
encoder cable for AM2000 / AM3000 can be used.
Connection
AX2000 to X1 and AX2500 to X2.
Dimension
Front view
Side view
Dimension:
Length (direction of move):
55 mm
Width:
50 mm
Hight:
30 mm
Direction of move
AX2000 / AX2500 AX5000 (X11 / X21)
Pin Pin
3 9
11 1
1 11
9 3
4 4
12 12
10 10
2 2
Wiring for AX2000 / AX2500 and AX5000:
See also other documents in the category BECKHOFF Equipment:
- Bus Terminal System (19 pages)
- EP-xxxx-xxxx (19 pages)
- BK2000 (30 pages)
- LC3100 (67 pages)
- BK4000 (28 pages)
- BK3xx0 (95 pages)
- BK5000 (12 pages)
- LC5200 (32 pages)
- BK7000 (29 pages)
- BK7500 (32 pages)
- BK7300 (40 pages)
- BK8100 (26 pages)
- BC2000 (28 pages)
- BC3100 (51 pages)
- BC7300 (48 pages)
- BC8100 (36 pages)
- BC3150 (112 pages)
- KL1012 (2 pages)
- KL1114 (2 pages)
- KL1164 (1 page)
- KL1232-xxxx (4 pages)
- KL1501 (19 pages)
- KL1512 (15 pages)
- KL2521-0024 (18 pages)
- KL2512 (21 pages)
- KL2612 (4 pages)
- KL2622 (9 pages)
- KL3062 (24 pages)
- KL3064 (20 pages)
- KL4132 (19 pages)
- KL4034 (25 pages)
- KL3302 (23 pages)
- KL3351 (18 pages)
- KS3681 (43 pages)
- KL4112 (18 pages)
- KL5001 (16 pages)
- KL5051 (17 pages)
- KL5101-0012 (21 pages)
- KS5111-0000 (21 pages)
- KL5121 (19 pages)
- KL6021 (20 pages)
- KL6051 (17 pages)
- Z1000 (2 pages)
- KL6071 (12 pages)
- Z1003 (2 pages)