AX2090NF50 (for AX5160AX5193)
Appropriate use
The mains filters of the series “AX2090NF50“ are exclusively intended for application in the control cabinet as
power supply unit of the AX5000. The filters are installed together with the servo drive as components in electrical
systems and machinery and may only be used in this way.
Safety rules and Personnel qualification
This description is only intended for trained specialists in control, automation and drive engineering who are familiar
with the applicable national standards. Knowledge of machine safety legislation is compulsory.
The responsible staff must ensure that the application or use of the products described satisfy all the requirements
for safety, including all the relevant laws, regulations and guidelines.
DANGER
Serious risk of injury through electric shock!
Even when the AX5000 is disconnected from the mains voltage, dangerous voltage continues to
be present at the "X02" terminals of the DC link: AX5160/AX5172 = 15 min., AX5190/AX5191 =
30 min. and AX5192/AX5193 = 45min.. Never touch the terminals within this period.
WARNING
Risk of injury!
Electronic equipment is not failsafe. The machine manufacturer is responsible for ensuring that
the connected motors and the machine are brought into a safe state in the event of a fault in the
drive system.
Technical data
AX2090NF50
Data
0063
0100
0150
0180
Rated voltage [V AC]
480 +10%
Rated frequency [Hz]
50 / 60
Rated current [A]
63
100
150
180
Ambient temperature [°C]
45
Relative air humidity
15%...85%, Condensation not permitted
Permissible contamination
P2 to EN 615581
Storage and transport temperature [°C]
25...+70 / 40…+85
Mounting height [m]
1000 (with power reduction 4000)
(6% / 1000 m)
Protection
IP 20 (AX2090NF500180 = IP00)
Leakage current [mA]
6,8
9,8
9,8
9,8
Weight [kg]
5,0
6,0
6,8
7,0
Listings UL/CSA
UL/CSA
UL/CSA
UL/CSA
Mains filter