beautypg.com

Servicing and maintenance, Cleaning the control panel, Servicing – BECKHOFF CP60xx User Manual

Page 15: Replacing the fluorescent lamps in the display

background image

Operating Instructions


Servicing and maintenance

Please also refer to chapter

General Notes

.

Cleaning the Control Panel

First switch off the Control
Panel

Switch off the Control Panel and all devices connected to it, so that keys
cannot be unintentionally actuated.

The front of the Control Panel can be cleaned with a soft, damp cleaning
cloth. Do not use any aggressive cleaning materials, thinners, scouring
material or hard objects that could cause scratches.

Servicing

The Control Panel is maintenance-free.

Replacing the fluorescent lamps in the display

Since fluorescent lamps represent a consumable item in a display, they
must be replaced after a few years, depending on the number of operating
hours.

The fluorescent lamps of the 6.5 inch, 12 inch and 15 inch displays can be
replaced by a technically competent person.

i

Note

Replacement of the fluorescent lamps may require partial
disassembly of the display!


Replacement for the
6.5 inch display

Press down the plastic clips
below the supply cable of the
lamps while you carefully pull
out the fluorescent lamps in
direction of the arrows.

After the exchange of the
fluorescent lamps the
installation takes place in
reverse order.


Replacement for the
12 inch display

First release the screw (2)
with a small Philips
screwdriver, then tilt the
fluorescent tubes with their
brackets (1) carefully
outwards.

After the exchange of the
fluorescent lamps the
installation takes place in
reverse order.

1

2

CP60xx

13