Electrical data – BECKHOFF C9900-P223 User Manual
Page 8
![background image](https://www.manualsdir.com/files/774584/content/doc008.png)
Product Description
6
C9900-P223 / C9900-P224
switch generally only has to be switched off if the control cabinet has to be
opened. The battery will only be used in the event of a power failure.
In order to maintain a screen display for the Industrial PC in the event of a
power failure, the C9900-P224 power supply unit is equipped with a UPS
output 27 V / 1.4 A for connecting a Control Panel with a display dimension
up to 19 inches. This enables a power failure to be visualized and
displayed to the user. Once the PC has shut down, the UPS output is
switched off.
For a detailed functional description please refer to section
External wiring
.
Electrical data
Input voltage: 22–30V
DC/
15A
Power output:
max. 150W, depending on cooling
Output voltages: +
5V
20A
+
12V
5A
+
5VSB
1A