beautypg.com

Electrical data – BECKHOFF C9900-P223 User Manual

Page 8

background image

Product Description

6

C9900-P223 / C9900-P224

switch generally only has to be switched off if the control cabinet has to be
opened. The battery will only be used in the event of a power failure.


In order to maintain a screen display for the Industrial PC in the event of a
power failure, the C9900-P224 power supply unit is equipped with a UPS
output 27 V / 1.4 A for connecting a Control Panel with a display dimension
up to 19 inches. This enables a power failure to be visualized and
displayed to the user. Once the PC has shut down, the UPS output is
switched off.

For a detailed functional description please refer to section

External wiring

.


Electrical data

Input voltage: 22–30V

DC/

15A

Power output:

max. 150W, depending on cooling


Output voltages: +

5V

20A

+

12V

5A

+

5VSB

1A